Skip to the content
Tundish · Permanent lining · AREL®

Permanent Linings

Dense castables that line the tundish shell and stay in place, campaign after campaign.

About the range

ARELCrete SF75 Ultra

A further development of the SF75 self-flowing, self-consolidating mid-alumina castable. It flows into place without vibration, for a dense, uniform permanent lining. This version gives significant heat retention advantages over the SF75 standard product

ARELCrete SF75

A self-flowing, self-consolidating mid-alumina castable. It flows into place without vibration, for a dense, uniform permanent lining.

ARELCrete LC17T

A high-duty low cement castable for higher temperatures, installed by vibration casting. Used in permanent lining applications for decades.

Why self-flow

With no vibrators there are no trailing cables or air lines across the bay, no hand-arm vibration for the installer, less noise, and fewer people needed for the pour.

Rapid cure

A 150 mm ARELCrete SF75 Ultra lining is air cured and dried in about 26 hours, where a typical low cement concrete takes about 90.

A tundish with its cast safety lining
Air curing and drying cycle for a 150 mm permanent lining: ARELCrete Ultra 26 hours, a typical concrete about 90 hours
Air curing and drying cycle for a 150 mm permanent lining.
Calculations assume 25mm minimum ARELSpray, stainless steel anchors and a molten steel temperature of 1560C

A lower shell temperature means less heat lost from the steel, less skulling, and less distortion of the shell over its life.

Jointing

ARELSet 80 HAS.

A ready-mixed, high-temperature air-setting cement, suitable for use up to 1750 °C, for jointing in the tundish.

Jointing cement being applied in a tundish

Talk to our tundish team.

If you are reviewing your tundish practice, or you have a lining problem you have been living with, talk to our technical team.

or call +44 1902 880123